    Name Description
    Alternate1

    configures the system to apply the values entered to the Weld Design Criteria window for "Alternate 1 re-entrant cut radius" and "Alternate 1 re-entrant cut length" and "Alternate 1 re-entrant cut depth" and "Alternate 1 flange flush length." The TopFlangeCutOperation and BottomFlangeCutOperation on this end of this beam will be set to CopeFieldWeldN1FEMA.

    Alternate3

    instructs the system to use the "Re-entrant cut radius" that is entered in Weld Design Criteria. The TopFlangeCutOperation and BottomFlangeCutOperation on this end of this beam will be set to CopeFieldWeldN3Standard.

    Automatic

    Decides between Alternate3 and Alternate1 based on setup options